Skip to content
Topic: Interface & Cable DiagnosticsSwitch

1.0 Network Infrastructure and Connectivity

Interface & Cable Diagnostics Practice Questions

Updated for CCNA v2.0

Collisions, errors, duplex and speed mismatches, copper and fibre limits, pinouts, and optical signal levels.

CCNA v2.0 objective 1.1 · objective map

Author-reviewed by LabFabric · 25 September 2026 · Report a content issue

All 11 Interface & Cable Diagnostics questions in this set

Answers and explanations appear when you work through the set above.

  1. One end of a link is hard-coded to 100 Mb/s full duplex and the other end is set to auto. What outcome is typical on a Cisco switch?

    • The auto end detects 100 Mb/s but uses half duplex, creating a mismatch
    • Both sides negotiate 1 Gb/s
    • The link stays down permanently
    • The auto end infers full duplex from the detected speed and matches the hard-coded end without negotiation
  2. In a duplex mismatch, which side typically reports late collisions and which reports CRC and runt errors?

    • Half duplex: late collisions. Full duplex: CRC and runt errors
    • Both ends report late collisions but neither end records CRC or runt errors
    • The full-duplex side reports late collisions and the half-duplex side reports CRC errors
    • Neither end reports errors, because Ethernet automatically corrects a duplex mismatch
  3. Which maximum length applies to a Cat 5e or Cat 6 copper Ethernet link for 1000BASE-T?

    • 100 meters
    • 10 metres
    • 550 metres
    • 1 kilometre
  4. A fiber link between two switches will not come up. The technician suspects transmit and receive fibers are reversed. What is the usual fix?

    • Swap Tx and Rx fibers at one end
    • Replace the switch with a router
    • Change the port to trunk mode
    • Enable PortFast on both ports
  5. Which fiber type is designed for long distances, such as 10 km or more, using a very small core?

    • Single-mode fiber
    • Multimode OM1 fiber
    • Cat 6a copper
    • Coaxial cable
  6. A single-mode optic is connected to a multimode fiber patch cord with a matching connector. What is the likely result?

    • High loss or unreliability from the optic/fiber mismatch
    • The link works normally at full distance
    • The link works, but only in half duplex
    • The switch automatically converts the light wavelength
  7. An engineer needs to check the received optical power on an SFP. Which type of output would show it, if the module supports digital diagnostics?

    • Transceiver diagnostics with Rx power in dBm
    • show ip interface brief, reading optical power from Status
    • show vlan brief
    • show running-config
  8. A fiber link comes up but has many CRC errors, and the Rx power is far lower than the optic's specification. Which action is most appropriate first?

    • Clean connectors and inspect cords and splices
    • Change the access VLAN to match the upstream switch management VLAN
    • Enable spanning tree PortFast edge trunk on each optical interface
    • Reduce the interface MTU to increase received optical power for shorter frames
  9. Which cable type is needed to connect two switches by copper if neither switch supports Auto-MDIX?

    • Crossover
    • Straight-through
    • Rollover
    • Coaxial
  10. In a T568B straight-through Ethernet cable, which two pairs carry data on a 10/100 Mb/s link?

    • Pins 1, 2, 3 and 6
    • Pins 4, 5, 7 and 8
    • Pins 1, 4, 5 and 8
    • Pins 3 and 4 as the transmit and receive pair
  11. Which show command lists interface error counters such as CRC, runts and collisions in a compact per-port table on a Catalyst switch?

    • show interfaces counters errors
    • show ip route summary
    • show cdp neighbors detail
    • show spanning-tree summary totals